SANITARY RTD BREWING SENSOR

REOTEMP’s Sanitary RTD sensors are specifically designed for direct insertion into sanitary process applications when a standard thermowell is not specified or the process environment is not exposed to pressure. Sanitary RTD’s are ideal for brewing, beverage, wine and distilling industries.

  • 3-A Approved Wetted Surfaces (32 Ra Max.)
  • 3-A Certificate Included
  • Sanitary Tri-clamp Design
  • 316SS Wetted Materials
  • Fully Sealed for Washdown (IP67)

rdpn-t15a040-as3.png

Tri-Clamp Size “D” Diameter (in)
1.5″* 1.98″
2″ 2.52″

*1.5″ Tri-Clamp fits 1.5″ and 1″ Tri-Clamp Fittings

RTD 100 ohm Pt., 0.00385 Ω/0ºC, 3-wire or 4-wire
Accuracy Class A, C = ± (0.15 + 0.0028*(t)) [-100/400ºC only]
Temperature Range -328ºF to 600ºF
Process Connection Tri-clamp (std); various sizes.
Stem Length 2” to 12” std lengths; custom lengths available.
Stem Diameter 1/4”
Wetted Finish Ra20
Connector M12 Quick 4-pin Quick Connect
Transmitter None