Configure Product Now
Request a Quote

SLIMLINE™ SANITARY RTD SENSOR/TRANSMITTER

Reotemp’s Slimline™ Sanitary RTD is a compact sensor/transmitter designed for direct insertion into sanitary tri-clamp systems and applications. The Slimline’s 3-A approved 316 stainless steel wetted surfaces are highly polished to reduce the risk of unsanitary conditions.

  • 3-A Approved 316SS Wetted Surfaces (32 Ra max.)
  • Configurable with Optional Transmitter
  • 3-A Certificate Provided
  • Sanitary Tri-clamp Design
  • Fully Sealed for Washdown (IP67)

Sensor Specifications

Environmental Conditions
Maximum Process Temperature -328/400°F
Common Specifications
Wire Types Teflon insulated 24 AWG stranded, PVC insulated 24 AWG Stranded, or Teflon insulated 24 AWG Stranded with Aluminum Mylar Shield and Drain Wire
Wetted Material 316 Stainless Steel
Housing Material 316 Stainless Steel
Wetted Finish Ra 32 Max. / Ra 20 Max.(Optional)
RTD Accuracy Class A = ± (0.15 + 0.002|t|)°C [-30/200°C] 1/10 B = ± (0.03 + 0.0005|t|)°C [ 0/50°C] Outside of State Ranges = ± (0.3 + 0.005|t|)°C [ -200/200°C]
Input Specifications
RTD Type Pt100, Ni100
Observed Authority Requirements
RoHS 2011/65/EU

Transmitter Specifications

Environmental Conditions
Ambient Temperature -40/185°F
Relative humidity <95% relative humidity (non-condensing)
Common Specifications
Supply Voltage 8.0 to 35 VDC
Internal Power Dissipation 25 mW to 0.8 W
Response Time (Programmable) 0.33 to 60s
Voltage Drop 8.0 VDC
Warm-up Time 5 min.
Effect of Supply Voltage Change < 0.005% of Span / VDC
Accuracy Better than 0.1% of selected range + RTD Accuracy
EMC Immunity Influence <±0.5% of Span
Output Specifications
Updating Time 135 ms
Signal Range 4-20 mA
Min. Signal Range 16 mA
Load (@ current output) ≤ (Vsupply – 8) / 0.023 [Ω]
Load Stability ≤ 0.01% of span /100Ω
Sensor Error Indication Programmable 3.5 to 23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
Of Span = of the presently selected range
Input Specifications
Cable Resistance Per Wire 10 Ω (max.)
Sensor Current > 0.2 mA, < 0.4 mA
Effect of Sensor Cable Resistance (3-wire) < 0.002 Ω/Ω
Sensor Error Detection Yes
Max. Offset 50% of selected max. value

Download Data Sheet:

Sanitary-Slimline-TRC-1020

Download Installation, Operation and Maintenance Instructions: