Diaphragm Seal Accuracy – How Temperature Impacts Pressure Reading
Threaded Diaphragm Seal Temperature Rating
| Process Temp °F | MWP 1500 psi | MWP 2500 psi | MWP 5000 psi | MWP 10000 psi |
| -40 to 100 | 1500 | 2500 | 5000 | 10000 |
| 200 | 1290 | 2150 | 4300 | 8600 |
| 300 | 1175 | 1950 | 3900 | 7800 |
| 400 | 1090 | 1800 | 3600 | 7200 |
| 500 | 1000 | 1650 | 3300 | 6600 |
| 650 | 910 | 1500 | 3000 | 6000 |
Temperature Dissipation by Diaphragm Seal Mount Type

| ANSI B16.5 Flange Rating (Temperature/Pressure) | |||||
|---|---|---|---|---|---|
| 316SS | Process Temp °F | Class 150 psi | Class 300 psi | Class 600 psi | Class 1500 psi |
| -40 to 100 | 275 | 720 | 1440 | 3600 | |
| 200 | 230 | 600 | 1200 | 3000 | |
| 300 | 205 | 540 | 1080 | 2700 | |
| 400 | 190 | 495 | 995 | 2485 | |
| 500 | 170 | 465 | 930 | 2330 | |
| 650 | 125 | 430 | 860 | 2150 | |
| Carbon Steel | -40 to 100 | 285 | 740 | 1480 | 3705 |
| 200 | 260 | 675 | 1350 | 3375 | |
| 300 | 230 | 655 | 1315 | 3280 | |
| 400 | 200 | 635 | 1270 | 3170 | |
| 500 | 170 | 600 | 1200 | 2995 | |
| 650 | 125 | 535 | 1075 | 2685 | |